Energy and backup power · Calculator

Air conditioner or heater: what does the same amount of heat cost?

Compare an air conditioner (heat pump) and a resistive heater for the same amount of heat: electricity and cost per day in two weather scenarios, the season in total, the payback of the more expensive appliance, the break-even coefficient of performance, and the maximum tariff and maximum heating hours within your budget.

Estimate based on your numbers Formula shown Your data stays in your browser

Your data

1. Shared inputs: tariffs and appliances

Day and night tariffs, heater efficiency, additional power and standby of the appliances, prices for the payback and a budget for working backwards. Amounts are in your currency.

Your tariff; an example, not a current price.
I don’t know this value

How to get this number

The price per 1 kWh is on your electricity bill, in your online account or in your contract with the electricity supplier. With two-rate metering, the day and night prices are shown there separately.

What you can calculate without it: Air conditioner: electricity per season, Heater: electricity per season, A: air conditioner electricity per day, A: heater electricity per day, A: effective coefficient of performance, A: break-even rated COP, B: air conditioner electricity per day, B: heater electricity per day, B: effective coefficient of performance, B: break-even rated COP, A: maximum average tariff within the budget (air conditioner), A: maximum average tariff within the budget (heater)

If you do not have a two-rate meter, enter the same as the day tariff.
I don’t know this value

How to get this number

The price per 1 kWh is on your electricity bill, in your online account or in your contract with the electricity supplier. With two-rate metering, the day and night prices are shown there separately.

What you can calculate without it: Air conditioner: electricity per season, Heater: electricity per season, A: air conditioner electricity per day, A: heater electricity per day, A: effective coefficient of performance, A: break-even rated COP, B: air conditioner electricity per day, B: heater electricity per day, B: effective coefficient of performance, B: break-even rated COP, A: maximum average tariff within the budget (air conditioner), A: maximum average tariff within the budget (heater)

Almost always 100%: all the electricity becomes heat.
Fans, electronics: ONLY if they are not included in the coefficient of performance according to your source; otherwise 0.
The fan of a fan heater and the like; 0 if there is none.
Including installation; an example.
An example.
For working backwards in scenario A: the maximum tariff and the maximum hours per day.
2. Scenario A (for example, moderate cold)

Weather in which the air conditioner works efficiently. Working backwards (maximum tariff, maximum hours) is done for this scenario.

How much heat is needed while the appliance is heating. This is not a calculation of the house’s heat losses. Enter your own estimate.
The compressor or the heating coil does not run continuously; the rest of the time is standby.
How many kWh of heat per 1 kWh of electricity according to the appliance’s spec sheet. An example, not your model.
I don’t know this value

How to get this number

Work out the heating coefficient of performance (COP) from your model’s technical data: heating capacity ÷ power input in heating mode, both in kW. If the manufacturer gives data for several outdoor temperatures, take the one closest to the weather in this scenario.

What you can calculate without it: Heater: cost per season, Heater: electricity per season, A: heater per day, A: heater electricity per day, A: break-even rated COP, B: air conditioner per day, B: heater per day, B: air conditioner electricity per day, B: heater electricity per day, B: effective coefficient of performance, B: break-even rated COP, A: maximum average tariff within the budget (heater), A: maximum scheduled hours per day within the budget (heater)

By what percentage the real COP is lower than the rated one in this weather. An example.
The share of all the appliance’s electricity at the night tariff.
0 means there is no such scenario.
3. Scenario B (for example, freezing weather)

Weather with a higher demand and a worse COP. 0 days means there is no such scenario.

How much heat is needed while the appliance is heating. This is not a calculation of the house’s heat losses. Enter your own estimate.
The compressor or the heating coil does not run continuously; the rest of the time is standby.
How many kWh of heat per 1 kWh of electricity according to the appliance’s spec sheet. An example, not your model.
I don’t know this value

How to get this number

Work out the heating coefficient of performance (COP) from your model’s technical data: heating capacity ÷ power input in heating mode, both in kW. If the manufacturer gives data for several outdoor temperatures, take the one closest to the weather in this scenario.

What you can calculate without it: Heater: cost per season, Heater: electricity per season, A: air conditioner per day, A: heater per day, A: air conditioner electricity per day, A: heater electricity per day, A: effective coefficient of performance, A: break-even rated COP, B: heater per day, B: heater electricity per day, B: break-even rated COP, A: maximum average tariff within the budget (air conditioner), A: maximum average tariff within the budget (heater), A: maximum scheduled hours per day within the budget (air conditioner), A: maximum scheduled hours per day within the budget (heater)

By what percentage the real COP is lower than the rated one in this weather. An example.
The share of all the appliance’s electricity at the night tariff.
0 means there is no such scenario.

How we calculate

  1. active hours = scheduled × share of time running; useful heat = demand × active hours; effective COP = rated × (1 − losses)
  2. air conditioner electricity = heat ÷ effective COP + additional × active + standby × (24 − active); heater = heat ÷ efficiency + its additional and standby; cost = kWh × (day × (1 − night share) + night × night share)
  3. break-even rated COP = heat ÷ ((heater electricity − air conditioner additional electricity) × (1 − losses)); season = daily cost A × days A + daily cost B × days B; payback = price difference ÷ seasonal saving; maximum tariff = budget ÷ (30 × kWh per day); maximum hours = (budget ÷ 30 ÷ weighted tariff − 24 × standby) ÷ (share of time running × (demand ÷ efficiency + additional − standby)), no more than 24

Assumptions

  • Both appliances deliver the same useful heat; the night share applies to all of the appliance’s electricity; standby lasts for the rest of the day.
  • The coefficient of performance, cold-weather losses and share of time running are your estimates for each scenario; enter the air conditioner’s additional power only if it is not included in the COP. change
  • Working backwards is done for scenario A over 30 days; the maximum hours are capped at 24 per day.

Limitations

  • Not a model of the house’s heat losses: air infiltration, thermal bridges, thermostat dynamics, sizing and the air conditioner’s operating limits in freezing weather are not calculated.
  • The coefficient of performance depends on the outdoor temperature, and the two scenarios reflect this only roughly.
  • The tariffs, appliance prices and COPs in the default values are examples, not current data.

Sources

A universal formula with no external constants. Default values are labelled as approximate examples, not verified facts.

Questions and answers

What is the coefficient of performance and where do I find it?

It is how many kilowatt-hours of heat the appliance delivers for each kilowatt-hour of electricity. The air conditioner’s spec sheet gives it for standard conditions; in freezing weather the real figure is lower. That is what the losses field is for.

Why two scenarios?

Because the air conditioner’s COP falls with the temperature: in moderate cold it saves a lot, in freezing weather little or nothing. Split the season into two types of weather and set the number of days for each.

Is the additional power included in the COP?

It depends on the data source. If the COP already includes fans and electronics, leave the additional power at 0; otherwise the electricity will be counted twice.

Why are the maximum hours capped at 24?

Because a day does not get any longer: if the budget allows more, the calculator shows 24 hours and warns that the real costs will be below the budget.

Related tools

This is a cost comparison based on your assumptions, not a heat load calculation for the house: take heat losses, the air conditioner’s operating limits in freezing weather, appliance power and tariffs from the documentation. The default values are examples, not the specifications of your appliances.

Formula version ac-vs-heater@1.1.0 · checked 26 September 2026

Checked by the Calc editorial team: three independent implementations of the formula, test cases and the live page on a phone. Last check: 27 September 2026