Energy and backup power · Calculator

How many hours will a power station last?

Add your devices, enter their power and the share of time they run, and the calculator accounts for the usable share of the battery, conversion losses and a reserve and shows the estimated runtime.

Estimate Formula shown Your data stays in your browser

Your data

1. Power station

Figures from the station’s spec sheet or casing. Capacity is needed in watt-hours.

The casing usually shows watt-hours (Wh). If only amp-hours and the battery voltage are given, choose the second option.
The figure from the station’s spec sheet or casing.
I don’t know this value

How to get this number

The rated capacity in watt-hours is written on the station’s casing or in its spec sheet. If the manufacturer gives only amp-hours and the battery voltage, choose “Voltage × amp-hours” above: their product is the capacity.

What you can calculate without it: Average load, Capacity needed for the desired runtime

The nominal battery voltage from the spec sheet: in lithium iron phosphate stations, 12.8 V for 4 cells, 25.6 V for 8, 51.2 V for 16.
The figure from the battery’s spec sheet. Capacity in watt-hours = voltage × amp-hours.
Not all of the rated capacity is usable: the battery management system cuts off part of it. If you do not know, leave 90%.
Inverter losses on the way to the 220 V socket. For devices powered directly from low-voltage outputs, the losses are smaller.
The share of capacity you do not plan to use: for the unexpected, or so as not to drain the battery to zero.
How much the station itself draws with the inverter on and no load. It is in the spec sheet or can be measured with a watt meter.
2. Devices

Take the power from the label on the device or its power supply, not from an advertising table. The share of time is the percentage of time the device actually runs.

Devices Share of time is the percentage of time a device actually runs: a fridge about a third, a router all the time.
I don’t know this value

How to get this number

The power is shown on the rating plate on the casing, in the spec sheet or on the power adapter, in watts (W). If only the current in amps (A) is given, multiply it by the voltage shown in the same place; this gives an upper estimate.

This tip applies to every row in this list.

3. Reverse calculation

How much capacity is needed for the desired number of hours with the same devices and adjustments.

How many hours the station should last. The calculator works out the capacity needed.

How we calculate

  1. average load = own consumption + Σ(power × quantity × share of time)
  2. usable energy = capacity × usable share × efficiency × (1 − reserve)
  3. time = usable energy ÷ average load
  4. capacity needed = desired time × average load ÷ (usable share × efficiency × (1 − reserve))

Assumptions

  • Devices are modelled by their average power; surge currents are not counted in watt-hours.
  • One conversion efficiency factor for the whole load. change
  • The usable share of the battery and the reserve are your values or the default 90% and 10%. change

Limitations

  • Surge currents of compressors and pumps are not modelled in watt-hours: they can stop the station before the energy runs out.
  • Temperature, battery ageing and the behaviour of the management system are not taken into account.
  • Typical device powers are starting points. For planning, take the figure from the label, the spec sheet or a watt meter.

Sources

A universal formula with no external constants. Default values are labelled as approximate examples, not verified facts.

Related tools

This is an engineering estimate, not a guarantee: the real result depends on conditions the calculator cannot see. Check the assumptions and limitations.

Formula version battery-runtime@1.2.0 · checked 25 September 2026

Checked by the Calc editorial team: three independent implementations of the formula, test cases and the live page on a phone. Last check: 27 September 2026